-40%
Timer Relay DC 12V 24V Time Delay Relay Controller Board, PEMENOL LCD Display Di
$ 11.08
- Description
- Size Guide
Description
Timer Relay DC 12V 24V Time Delay Relay Controller Board, PEMENOL LCD Display Digital Timer Switch Trigger Cycle Timer Module for Smart Control Power On-Off ControllerProduct Description
Multifunction delay relay module
Cycle timing circuit switch
Support high and low level trigger
Automatically save parameters
Emergency stop function
Widely used at Smart home,Industrial control
Features
*LCD display
*Support high and low level trigger
*Support button trigger
*Emergency stop function
*Sleep mode,Wake up with any button
*Automatically save parameters
*Support UART Set
*Independent of parameters
*With case, beautiful and practical
*Support reverse connection protection
*Delay high precision
*Continuously adjustable from 0.01 seconds to 9999 minutes
*Optocoupler isolation.Enhanced anti-jamming capability
*Multiple parameters are displayed simultaneously
Additional Features:
1>.Auto sleep function: Long press button 'Pause' in the normal running interface(P0~P7) to turn on or off auto sleep function.
L-P:ON,Turn ON auto sleep function.About five minutes, no operation, the LCD backlight automatically turns off.It can be wake up by any buttons.
L-P:OFF,Turn OFF auto sleep function.
2>.View parameters: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system.
3>.Switch the display parameter: It will switch the display content by short press button 'DOWN' in the P5~P6 mode(Parameter is Run time or number of cycles)
Work mode
P0:Rela
y will keep ON for time OP after getting trigger signal and then relay OFF; The input signal is invalid if get trigger signal again during delay time OP.
P1:
Relay will keep ON for time OP after getting trigger signal and then relay OFF; Module will retime if get trigger signal again during delay time OP.
P2:
Relay will keep ON for time OP after getting trigger signal and then relay OFF; Module will reset and stop timing if get trigger signal again during delay time OP.
P3:
Relay will keep OFF for time CL after getting trigger signal and then relay keep ON.
P4:
Relay will keep ON for time OP after getting trigger signal and then relay keep OFF for time CL and then repeats the above action. The module will reset and stop timing and the relay will keep the initial state if get the trigger signal again during loops. The number of cycles (LOP) can be set. The relay will keep OFF if the end loop.
P5:
Relay will keep OFF for time CL after getting trigger signal and then relay keep ON for time OP and then loops the above action. The module will reset and stop timing and the relay will keep the initial state if get the trigger signal again during loops. The number of cycles (LOP) can be set. The relay will keep ON if the end loop.
P6:
Relay will keep ON for time OP after power on without getting trigger signal and then relay keep OFF for time CL and then loops the above action. The number of cycles (LOP) can be set. The relay will keep OFF if the end loop.
P7:
Relay will keep OFF for time CL after power on without getting trigger signal and then relay keep ON for time OP and then loops the above action. The number of cycles (LOP) can be set. The relay will keep ON if the end loop.
P8:
Signal hold function. Reset delay time and relay keep ON if keep getting trigger signal. Relay OFF when the signal disappears after delay time OP. Reset delay time when getting trigger signal again during timing.
P9:
Signal hold function. Reset delay time and relay keep OFF if keep getting trigger signal. Relay ON when the signal disappears after delay time CL.Reset delay time when getting trigger signal again during timing
P0~P7 mode:
System will start to delay if the short press button ‘Pause’ when the system does not get the trigger signal. The display screen will display ‘OUT’ and flashing and Relay OFF when Pause timing if the system has been timed.
P8~P9 mode:
Other buttons cannot be used when the ‘Pause’ button is a trigger signal in the running interface.
Timing range setting
0.01 second (minimum) ~ 9999 minutes (maximum) continuously adjustable
In the OP/CL parameter modification interface,Short press the "Pause" button,select timing range
Display ‘XXXX’.No decimal point, the timing range is 1 second ~ 9999 seconds.
Display ‘XXX.X’.The decimal point is the penultimate, timing range is 0.1 second to 999.9 seconds.
Display ‘XX.XX’.The decimal point is the third last, timing range is 0.01 second to 99.99 seconds.
Display ‘X.X.X.X’.The decimal point is fully lit, timing range is 1 minute to 9999 minutes.
F
or example,
if you want to set the OP to 3.2 seconds, move the decimal point to the penultimate position, the LCD will display ‘003.2’.
Parameter Description:
OP: Turn On-time;
CL: Turn OFF time;
LOP: Number of cycles.The range is 1-9999tims.’----’ means unlimited loop.
Parameter settings:
Long press: keep press the button for more than 3second.
1>. Enter set parameter menu by long press button 'SET'.
2>. Work mode will flash at first set the working mode. Short press the UP/DOWN button to set the working mode.
3>. Short press the SET button to select the working mode and enter the system parameter settings.
4>.In the system parameter setting interface, short press the ‘SET’ button to switch the system parameters to be modified, short/long-press the UP/DOWN button to modify value;
Note: Short press ‘SET ’ is invalid at mode P0, P1, P2, P3, P7, P8.
5>. Enter setting interface when short press button ‘Pause’ in the OP/CL parameter modification interface(Flashing) to select timing range (1s/0.1s/0.01s/1min).
6>. Save the parameter settings and exit the settings interface when long-press the ‘SET’ button after all the parameters are set.
Note:
It is a relay output mode and cannot be used as a power module. It cannot output voltage. The load needs to be connected to a separate power supply.
Application
Motor
Robot
Smart home
Industrial control
Automatic irrigation
Indoor ventilation
Parameters
Working Voltage:DC 6V-30V
Control Load Current:10A(Max)
Quiescent Current:15mA
Working Current:50mA
Working temperature: -40~85℃
Operating Humidity:5%-99%RH
Suitable for battery:Storage Battery,Lithium battery
Trigger signal source: High level trigger (3.0V~24V), Low level trigger (0.0V~0.2V), switching control (passive switch)
Physical dimension:79*44*26mm
Function
1>.Trigger delay.
The module will begin to delay after getting a trigger signal. And output terminal status will change after the delay. This function can be used in circuit protection from misoperation and prevent instantaneous high current.
2>.Cycle timing.
The load switch changes state according to the specified time after set cycle time.
3>. Delayed power off.
If you want to control a light that needs it to power off after some time. This module can meet this function.
4>.Circuit switch.
Protect the circuit from damage caused by the prolonged operation.
Work Voltage
DC 6V-30V
AC 85V-265V
DC 5-36V
DC 3.3V-30V
Timing Range
0.01s-9999mins
0s-999h
0.1s-999mins
0.000s~9999s
Display Mode
Auto Sleep Function
Dual Timing Time
Dual Mos Output
PWM and PULSE mode
★LCD display shows a variety of parameters: The current mode and parameters are clear at a glance, very clear, simple and practical. In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system. In P4 ~ P7 mode, short press the DOWN key to switch the display content (running time/cycle number)
★Support button trigger control: The relay module delay power off and trigger delay cycle timing circuit switch Support button trigger control, high and low level trigger, switch control, suitable for most occasions
★With reverse connection protection:This trigger delay cycle timing circuit switch has a key pause function, with reverse connection protection, the reverse connection does not burn
★Support UART data upload and parameter setting: You can set different OP, CL, LOP parameters, these parameters are independent of each other and saved separately. All set parameters are automatically saved after power-off. For more details, please read the user manual
★Automatic sleep function: in the running interface (P0~P7 mode), long-press the pause button to start or close the automatic sleep function (L-P selects on to start the sleep function, about five minutes, without any operation, the LCD backlight automatically turns off, the system Normal operation, press any button to wake up; press the off button to turn off the sleep function)
Shipping
Fast shipping is very important for us.
Our standard US shipping service is FREE.
Your order will be shipped within 1-4 business days upon full payment received.
Your order will be delivered within 2-10 business days after the handling time.
We don't normally ship to Outside of US , Alaska/Hawaii, APO/FPO,
US Protectorates such as
Puerto Rico.If you order for these location, handling time and shipping time will be longer (up to 21 days)
Once you place the order , we will not able to cahnge the address, or cancel the order. If you need to cancel, you'd need to return after you receive item.
We reserve the right to cancel any order for any reason at any time.
We are not responsible for undeliverable addresses.
Returns and payment
We offer a 30 days return policy from order date.
We allow PayPal and Credit Card as payment method.
FeedBack
Your feedback very important to us, after you get your package and if you are
satisfied with our service
please leave us a positive feedback !
If you have any problem with your order / any questions please before leave any type of feedback
For any questions, using eBay contact system
Please visit our eBay store to check out other items for sale!
Thank you for shopping at our store.