-40%
Insertion Electromagnetic Flow Meter, 20" Probe
$ 950.4
- Description
- Size Guide
Description
Insertion Electromagnetic Flow Meter, 20" Probe, Direct Mount, 4-20ma, Pulse, Hart, Hastelloy C Electrodes,18-28VDC, Electrode Cape PTFE, with Isolation Valve and Blowout Preventer, 1.5" MNPT Process ConnectionTek-Flux 1400B Insertion Electromagnetic Flow Meter is used to measure the flow rate of a variety of conductive liquids. It functions according to the fundamental principle of Faraday’s law of Electromagnetic Induction, which describes the relationship between an electrical conductor and the voltage it generates when moving within a magnetic field. In an Electromagnetic Flow Meter, a magnetic field is generated by a pair of diametrically placed electrical coils mounted external to the flow tube. As the conductive liquid passes through this Electromagnetic field, an electrical voltage is induced in the liquid, which is directly proportional to its velocity. This induced voltage is perpendicular to the directions of both the liquid flow and the electromagnetic field. A pair of diametrically placed electrodes mounted along the inner wall of the flow tube and in the direction of the induced voltage, sense this induced voltage. The sensed voltage is further processed by the Transmitter to indicate the flow rate and generate a standard output signal proportional to the measured flow rate.
Adjustable depth
Can be used in pipes from 4″ to 80″
Comes with isolation valve
No moving parts
Multiple Signal Outputs
Nominal Diameter
4″ to 80″
Working Process Pressure
250 psi
Electrode Material
Hastelloy C
Wetted Material
316 SS, Hastelloy C, PTFE
Flow Sensor Rating
IP66, NEMA4X
Minimum Liquid Conductivity
10µ siemens
Accuracy of Measured Value
±1% of span
Repeatability
±0.2% of Span
Measuring Range
0.65 to 39 ft/sec Bi-directional
Display Version
Integral
Display Type
16 characters x 2 row LCD, 5 Digit Flow rate and 8 Digit Totalizer
Units
Flow Rate
Totalizer
LPS, LPM, LPH, LPD
Mlps, Mlpm, Mlph, Mlpd
cc/s, cc/m, cc/h, cc/d
m3/s, m3/m, m3/h, m3/d
kg/s, kg/m, kg/h, kg/d
t/s, t/m, t/h, t/d
gps, gpm, gph, gpd
Mgps, Mgpm, Mgph, Mgpd
lgps, lgpm, lgph, lgpd
lMgps, lMgpm, lMgph, lMgpd
ft3/s, ft3/m, ft3/h, ft3/d
lb/s, lb/m, lb/h, lb/d
L, Ml, m³
Ml
L, Ml, cc, m³
L, Ml, m³
kg, t
T
G, ft³
Mg
lg, ft³
lMg
g, lg, ft³
lb
Current Output
4 to 20 mA and Pulse
Digital Output
HART
Power Supply
18 to 60 VDC
Electrical Connection
1/2″ NPT
Operating Temperature
-20°F to 250°F (-28°C to 120°C)
Process Connection
1.5” MNPT